Grandstream Networks, Inc. BT200 User Manual Page 25 of 33
Firmware 1.1.5.15 Last Updated: 01/2008
Use Random
Port
This parameter, when set to “Yes”, will force random generation of both the local SIP
and RTP ports. This is usually necessary when multiple BT200s are behind the same
NAT. Default is No.
Keep-alive
interval
This parameter specifies how often the BT200 sends a blank UDP packet to the SIP
server in order to keep the “hole” on the NAT open. Default is 20 seconds.
Use NAT IP
NAT IP address used in SIP/SDP message. Default is blank.
STUN Server
IP address or Domain name of the STUN server. STUN resolution result will display in
the STATUS page of the Web UI.
Firmware
Upgrade and
Provisioning
Default method is HTTP. Firmware upgrade may take up to 10 minutes depending on
network environment. Do not interrupt the firmware upgrading process.
Via TFTP Server
This is the IP address of the configured TFTP server. If selected and it is non-zero or not
blank, the BT200 will attempt to retrieve a new configuration file or new code image from
the specified TFTP server at boot time. It will make up to 3 attempts before timeout and
then it will start the boot process using the existing code image in the Flash memory. If a
TFTP server is configured and a new code image is retrieved, the new downloaded
image will be verified and then saved into the Flash memory.
Note: Grandstream strongly recommends that the user upgrade firmware locally in a
LAN environment if using TFTP to upgrade. Please do NOT interrupt the TFTP upgrade
process (especially the power supply) as this will damage the device.
Via HTTP
Server
The HTTP server URL used for firmware upgrade and configuration via HTTP. For
example: http://provisioning.mycompany.com:6688/Grandstream/1.1.5.15.
Here “:6688” is the specific TCP port that the HTTP server is using; omit if using default
port 80.
Note: If Auto Upgrade is set to No, BT200 will only perform HTTP download once at
boot up.
Config Server
Path
IP address or domain name of firmware server.
Firmware File
Prefix/Postfix
Default is blank. If configured, BT200 will request the firmware file with the prefix/postfix.
This setting is useful for ITSPs. End user should keep it blank.
Config File
Prefix/Postfix
Default is blank. End user should keep it blank.
Allow DHCP
Option 66 to
override server
Default is Yes. This allows device gets provisioned automatically.
Authenticate
Conf File
Default is “No”. If set to “Yes”, configuration file would be authenticated before
acceptance. End user should use default setting.